DATA STORAGE CAPACITY IN ESTIC NUTRUNNER
DATA STORAGE CAPACITY IN ESTIC NUTRUNNER
Data storage
capacity is one of the main concern points in all of the DC nutrunners . A customer always wants to get more space to store the data in DC nutrunner, the
customers who do not take the dynamic data on any server always demand the
higher space. This is also the main feature of DC nutrunners. Another point
is what type of data does DC nutrunner stored. So we talk about the ESTIC
fixture & Handheld nutrunner. Estic DC nutrunner stored three types of
data, one is fastening data which includes tightening torque, date, time,
count no, final angle, rundown angle, seat torque, fastening time, total
time, the program no, etc. Also when we use barcode or QR code for tracing the
particular data that data also save in
fastening data with a reference no of the barcode . Next is Torque curve data,
this is also very important to read the fastening process, it always helps in
finding the cause of NG, we can see the toque versus time data & torque
versus angle data. It shows the graph of fastening from start to finish &
give us clarity on various aspects of fastening. The last one is System error
data, this is also very important for the life of tool & controller.
System error data indicates that what part is causing the problem during
fastening like if we get a motor heating error that means motor is running for
long time, So we can take the correct action within time to protect our system
through system errors. Now we look below that how much capacity have the
controllers of handheld & fixture nutrunner :
HANDHELD CONTROLLER ( HANDY 2000LITE SERIES)
Handheld controller
stores 33000 records of fastening data, 30 records of torque curve data (20 OK
tightening , 10 NG tightening ) & 50
records of system error data.
AXIS CONTROL UNIT (FIXTURED Z50)
Axis unit stores
5115 records of fastening data & 50 records of system error data. This
controller does not save the torque curve history, this feature is only
available in the Master unit.
MASTER CONTROL UNIT (FIXTURED Z50)
Master control unit
saves 20000 records of fastening data, 200 records of system error & 50
records of torque curve data.